![]() If during the initialization of the switch-on the controller does not "feel" neutral = the display will show error 81 (lift) or 83 (accelerator). If it is less, then it may not gain speed. Thus, the deviation can be adjusted from 0.5 to 1 V. ![]() Confident operation from 1V down and from 1.5V up. The neutral corridor is set to 0.1V in the range of 1.2. The smaller the control voltage deviation, the smoother the ride. small changes in deviation, in principle, only affect the sensitivity and smoothness of the controller. The deviation in both directions is (0.5 + 0.5) = 1V. during the initialization process, when switched on, the state of the regulators is evaluated. To adjust variometers with a replaced non-programmable Hall sensor, for example SS49E, you can adapt any variometer based on the neutral voltage value, which is 1.25 V. To do this, you need to enter the mode learning through a password. ![]() The regulators of the Raymond RT35TT stacker for accelerator (1017546/002) and lift (1017546/002) are almost identical and are based on a variometer using a linear bipolar Hall sensor MLX90215, which assumes programming-learning (calibration) through the sensor output.